?!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> :吊顶式新风机?空调机组-新风机组-组合式空调机?德州凯亿空调厂家

  • <tr id='giTKF0'><strong id='giTKF0'></strong><small id='giTKF0'></small><button id='giTKF0'></button><li id='giTKF0'><noscript id='giTKF0'><big id='giTKF0'></big><dt id='giTKF0'></dt></noscript></li></tr><ol id='giTKF0'><option id='giTKF0'><table id='giTKF0'><blockquote id='giTKF0'><tbody id='giTKF0'></tbody></blockquote></table></option></ol><u id='giTKF0'></u><kbd id='giTKF0'><kbd id='giTKF0'></kbd></kbd>

    <code id='giTKF0'><strong id='giTKF0'></strong></code>

    <fieldset id='giTKF0'></fieldset>
          <span id='giTKF0'></span>

              <ins id='giTKF0'></ins>
              <acronym id='giTKF0'><em id='giTKF0'></em><td id='giTKF0'><div id='giTKF0'></div></td></acronym><address id='giTKF0'><big id='giTKF0'><big id='giTKF0'></big><legend id='giTKF0'></legend></big></address>

              <i id='giTKF0'><div id='giTKF0'><ins id='giTKF0'></ins></div></i>
              <i id='giTKF0'></i>
            1. <dl id='giTKF0'></dl>
              1. <blockquote id='giTKF0'><q id='giTKF0'><noscript id='giTKF0'></noscript><dt id='giTKF0'></dt></q></blockquote><noframes id='giTKF0'><i id='giTKF0'></i>
                德州凯亿空调设备有限公司

                空调机组,新风换气?新风机组,组合式空调机?空调?/p>

                全国服务热线13465343500
                山东金光消防排烟风机厂家
                当前位置?/b>

                吊顶式新风机?/h1>

                文章来源?span>www.kaiyikt.com

                发布时间?span>2019?2?6?/span>

                1.凯亿吊顶空调新风机组应水平安装于吊顶夹层内,冷凝水管侧允许偏低千分之五,但不允许偏高,以保证冷凝水的顺利排放。凯亿吊顶空调新风机组四周应留有充分的安装于维修空间?/p>

                2.与凯亿吊顶空调新风机组链接的冷凝水排放须设有水封,且水封要有足够的高度?/p>

                3.表冷器接水管为下进上出,在进水口处应加装截止阀、过滤器?/p>

                4.鱼凯亿吊顶空调新风机组链接的风管需柔性链接,与凯亿吊顶空调新风机组链接的水管应采用绕性接管,接管时扭力不应过大,以免损伤换热器。且管路须有单独支撑,重量大的由电凯亿吊顶空调新风机组承受?/p>

                5.凯亿吊顶空调新风机组供电电源?80V?0Hz。电源符合要求方可与电机相连,接通电源后,应检查风机转向是否正确,如反转,应停机将电源相序改变?/p>

                6.风机电机应有良好的接地,另须有过载,过热、缺项等其他可靠保护?/p>


                吊顶式新风机? onmousewheel=

                吊顶式新风机? onmousewheel=

                吊顶式新风机? onmousewheel=

                吊顶式新风机? onmousewheel=

                吊顶空调新风机组运行及维?/h3>

                1.凯亿吊顶空调新风机组的冷热媒应为纯洁的软化水,其工作压力不超?.6Mpa?/p>

                2.凯亿吊顶空调新风机组正常运行时风机轴承温度升不应超过40℃?/p>

                3.凯亿吊顶空调新风机组出水管装有排气阀,首次运行及冷热转换前须打开放气阀,排净换热器及管路内的空气,以免影响换热效果。凯亿吊顶空调新风机组夏季共冷水温度不低?℃,冬季供热温度不应高于80℃?/p>

                4.冬季严寒地区级全新风凯亿吊顶空调新风机组开机制热时,应先开加热?-10分钟,再启动送风机,防止大量冷空气在换热器内形成冰塞;停机时应先关闭新风阀,后关闭加热器,最好关闭送风机?/p>

                5.凯亿吊顶空调新风机组在冬季长期不用时,应将盘管内存水排空,并用压缩空气吹干,如存水不能吹干净,应在管内加防冻液。如凯亿吊顶空调新风机组在冬季段时间暂时不运行,应保证管内有热水循环,以防锈、防冻。除冬季外,换热器在其他季节停用时,也应将换热器充满水,以减少侵蚀?/p>

                6.过滤器应定期清洗,以保证凯亿吊顶空调新风机组使用效果,如发现风量减小,一般为过滤器积尘过多所致?/p>

                7.凯亿吊顶空调新风机组运行一个月后,应检查吊装紧固螺栓有无松动现象?/p>

                凯亿吊顶空调新风机组运行二至三年后,应进行全面保养,清楚换热器管内水垢,用压缩空气或水清洗换热器翅片。风机。电机等润滑部位应定期加注润滑油?/p>